120V 120V Home

Heat pumps, induction and water heaters on 120 volts, and the circuit each one needs.

Window heat pumps and 120 V heat pump water heaters plug into a wall outlet. Copper's battery range plugs into a standard outlet. 115 V mini splits are hardwired on their own circuit. We list the circuit each maker specifies, from its own sheets, dated. When we've measured one at the plug, we'll say so.

  • Window heat pumpsPlug-in units that heat and cool, no line setFit check
  • Water heaters120 V heat pump models designed to share a 15 A circuitCompared
  • Induction rangesA battery range with a 120 V, 12 A inputGuide
  • Mini splits115 V units, hardwired on their own circuitGuide

Circuit check: add up what shares a breaker

Type each appliance's nameplate amps or watts. The dashed line is 80% of the breaker, the usual sizing for loads that run 3 hours or more (NEC 210.20(A)). It's arithmetic only: the appliance's manual decides whether it may share a circuit.

    Type each value from the appliance's nameplate (the label on the back or bottom). Use its amps if it lists them. Watts are converted at 120 V, which gives the lowest current it could draw; the real current can be higher. An average or yearly energy figure is not a nameplate value, so don't use it here.

    0 A12 A, 80%15 A

    –

    Nothing entered yet. Add each appliance on the same breaker.

    Every product, by the maker's numbers

    Draw, breaker and price as each maker or seller states them. Where they don't publish a figure, the table says so.

    120V appliances compared
    ProductVoltsDraw (maker)BreakerHeats down toPrice checkedMore
    Heating and cooling
    Midea MAW12HV1CWT115not publishednot stated41°Fnot listedNov 22, 2026Fit check
    Gradient All-Weather 120V120not published15 A-13°Fnot listedNov 22, 2026Fit check
    Mini splits
    MRCOOL DIY 12K 115V110-120not publishednot stated-13°F$2,369Nov 22, 2026Fit check
    Pioneer Quantum 12K110-120not published25 A-13°F$1,163Nov 22, 2026Fit check
    Water heating
    Rheem ProTerra 120V shared120440 W average15 A37°F$2,119Nov 22, 2026Fit check
    A. O. Smith Voltex 120V120not published15 A–not listedNov 22, 2026Fit check
    Kitchen
    Copper Charlie Classic120not publishednot stated–$5,999Nov 22, 2026Fit check

    Know your outlet in five seconds

    A 15 A outlet has two straight slots. A 20 A outlet has a sideways T on one slot, and it also takes a 15 A plug. The breaker in your panel has the final say.

    NEMA 5-15 outlet: two straight vertical slots and a round ground hole
    NEMA 5-15R15 A · 1,800 VA at 120 V
    NEMA 5-20 outlet: one slot has a sideways T
    NEMA 5-20R20 A · 2,400 VA at 120 V

    Outlet ratings from the NEMA connector reference. Watts are amps × 120 V.

    Rebates, state by state

    On each state's own program page, at least one federal home energy rebate was taking some household applications in 7 of the 50 states and DC. 6 more had only limited channels or a waitlist. Checked Nov 22, 2026; most of those readings come from an independent review we haven't re-read yet. The federal 25C tax credit doesn't apply to equipment installed after 2025.

    • IndianaElectrification: Open. Efficiency: Open.Nov 22, 2026
    • MaineElectrification: Open. Efficiency: Not open yet.Nov 22, 2026
    • MichiganElectrification: Open. Efficiency: Open.Nov 22, 2026
    • New YorkElectrification: Open. Efficiency: Not confirmed.Nov 22, 2026
    • North CarolinaElectrification: Open. Efficiency: Open.Nov 22, 2026
    • Rhode IslandElectrification: Open. Efficiency: Open.Nov 22, 2026
    • WisconsinElectrification: Open. Efficiency: Open.Nov 22, 2026

    All 51 state pages · How the rebates work · Heat pump tax credit in 2026